CAN Output Messages

The PDM transmits the following messages at 20 Hz.
Note: only relevant messages get transmitted for a particular PDM type

CAN Address Byte Bit

Channel

Scaling

Base address
+ 0

0

4..7

Compound Id = 0

0

0

Input 1 State

0 = Inactive
1 = Active

1

0

Input 2 State

2

0

Input 3 State

3

0

Input 4 State

4

0

Input 5 State

5

0

Input 6 State

6

0

Input 7 State

7

0

Input 8 State

Base address
+ 0

0

4..7

Compound Id = 1

0

0

Input 9 State

0 = Inactive
1 = Active

1

0

Input 10 State

2

0

Input 11 State

3

0

Input 12 State

4

0

Input 13 State

5

0

Input 14 State

6

0

Input 15 State

7

0

Input 16 State

Base address
+ 0

0

4..7

Compound Id = 2

0

0

Input 17 State

0 = Inactive
1 = Active

1

0

Input 18 State

2

0

Input 19 State

3

0

Input 20 State

4

0

Input 21 State

5

0

Input 22 State

6

0

Input 23 State

Base address
+ 0

0

4..7

Compound Id = 3

1

0..7

PDM Internal
Temperature

0 to 125 = 0 °C to +125 °C
1 °C steps

2

0..7

PDM Battery
Voltage

0 to 255 = 0 V to 31 V
0.1216 V steps

3

0..7

Global Error Flag

0 = OK
1 = one or more outputs is in
either Fault or Over-Current error

4

0..7

Total Current

0 to 255 = 0 to 255 A
1 A steps

5

0..7

9.5V internal rail
voltage

0 to 255 = 0 V to 15.68 V
0.0615 V steps
Should read close to 9.5 V when
the Battery voltage is > 10.5 V

6

0..7

Reset Source