Pump wet end assembly – All-Flo A200-NAA-VVYV-000 2 Aluminum User Manual

Page 15

Advertising
background image

all-flo.com

15

7

SECTION

STEP 7

In order to remove both “Outer

Chambers” use two ¾ Inch

wrenches. Remove ten “Hex-

Head Cap Screws (1/2”-13x2”)”,

ten “Flat Washers (1/2”)” and

eight “Flanged Hex Nut (1/2”-13)”

from each “Outer Chamber”.

(Air ratchet may also be used as

shown in image)

STEP 8

Remove both “Outer Chambers”

from the “Intermediate.”

STEP 9

Using two 1 Inch wrenches,

remove “Outer Diaphragm Plate”,

“Diaphragm”, “Inner Diaphragm

Plate” and “Nut” from one side

of the pump.

STEP 10

Placing the 1 inch wrench on the

“Outer Diaphragm Plate”, and the

1 1/16 inch socket on the “Nut”,

remove the “Inner Diaphragm

Plate”.

STEP 11

Remove “inner diaphragm plate”

and “outer diaphragm plate” from

“diaphragm.”

PUMP WET END ASSEMBLY

To assemble the wet end of the pump, reverse the order of disassembly.

Ensure all hardware is fastened in accordance with torque specifications

(see page 18). Inverting one of the diaphragms during reassembly will

facilitate ease of assembly.