Cautions — read first, Warning, Caution – All-Flo A200-NAA-VVYV-000 2 Aluminum User Manual

Page 3: Warning caution

Advertising
background image

all-flo.com

3

SECTION

1

READ THESE WARNINGS AND SAFETY PRECAU-

TIONS PRIOR TO INSTALLATION OR OPERATION.

FAILURE TO COMPLY WITH THESE INSTRUCTIONS

COULD RESULT IN PERSONAL INJURY AND OR

PROPERTY DAMAGE. RETAIN THESE INSTRUCTIONS

FOR FUTURE REFERENCE.

WARNING

Pump, valves and all containers

must be properly grounded prior to handling

flammable fluids and/or whenever static electricity

is a hazard.

WARNING

Prior to servicing the pump,

ensure that the air and fluid lines are closed and

disconnected. While wearing personal protective

equipment, flush, drain and process liquid from the

pump in a safe manner.

CAUTION

Do not connect a compressed air

source to the exhaust port of the pump.

CAUTION

Ensure that the muffler is properly

installed prior to pump operation.

CAUTION

Do not lubricate air supply.

CAUTION

When selecting pump materials, be

aware of the following temperature limitations:

Buna-N (Nitrile):

10°F to 180°F (-12C to 82C)

Geolast

®

:

10°F to 180°F (-12C to 82C)

EPDM:

-40°F to 280°F (-40C to 138C)

Santoprene

®

:

-40°F to 225°F (-40C to 107C)

Viton

®

(FKM):

-40°F to 350°F (-40C to 177C)

PTFE:

40°F to 220°F (4C to 104C)

Polyethylene:

32°F to 158°F (0C to 70C)

Polypropylene:

32°F to 180°F (0C to 82C)

PVDF:

0°F to 250°F (-18C to 181C)

Nylon:

0°F to 200°F (-18C to 93C)

Temperature limits are solely based upon

mechanical stress and certain chemicals will reduce

the maximum operating temperature. Consult a

chemical resistance guide for chemical compatibility

and a more precise safe temperature limit.

CAUTIONS — READ FIRST!

WARNING

CAUTION

= Hazards or unsafe practices

which could result in severe

personal injury, death or

substantial property damage

= Hazards or unsafe practices

which could result in minor

personal injury, product or

property damage.

CAUTION

Do not exceed 120 psig (8.3 bar)

air-inlet pressure.

CAUTION

Ensure all wetted components are

chemically compatible with the process fluid and the

cleaning fluid.

CAUTION

Ensure pump is thoroughly cleaned

and flushed prior to installation into a process line.

CAUTION

Always wear Personal Protective

Equipment (PPE) when operating pump.

CAUTION

Close and disconnect all

compressed air and bleed all air from the pump

prior to service. Remove all process fluid in a safe

manner prior to service.

CAUTION

Blow out all compressed air

lines in order to remove any debris, prior to

pump installation.

CAUTION

Ensure air exhaust is piped to

atmosphere prior to a submerged installation.

CAUTION

Ensure all hardware is set to

correct torque values prior to operation.

Advertising