PILOT VALVE REMOVAL

STEP 1

Using the screwdriver, remove

three “Phillips Pan Head Mach

Screw (#6-32-x 3/8”)” in order to

remove the “Retaining Plate”.

Repeat for both sides of the pump.

STEP 2

Remove the “diaphragm rod” and

the “pilot sleeve assembly” from

the “Intermediate”.

TOOLS NEEDED

1) One Screwdriver, Phillips
2) Two Wrenches, 1/2 Inch
The chambers do not need to be

removed for this procedure.

The graphics show the inner

chambers removed for clarity.

WARNING

Prior to servicing the pump, ensure that the air and

fluid lines are closed and disconnected. While wearing personal

protective equipment, flush, drain and process liquid from the pump

in a safe manner.

STEP 3

Remove the “lip seal” and “end

spacer”.

STEP 4

Remove “o-rings” and “inner

spacer”.

REPAIR AND ASSEMBLY

STEP 5

Remove “pilot sleeve” from

diaphragm rod. The two piece rod

must be disassembled to remove

the “pilot sleeve”.