Temperature adjustment, Configuration and parameters view – KOSPEL KDE User Manual

Page 24

Advertising
background image

24

ER>T INLET – inlet sensor failure,

ER> T OUTLET – outlet sensor failure,

ER> T MAX – temperature has exceeded the maximum value,

ER> AIR 1 – air bubbles in the heating box – equipment detection,

ER> AIR 2 – air bubbles in the heating box – program detection.

If the display shows ER> T MAX, ER> AIR 1 or ER> AIR 2 the unit will stop heating.

The unit will not heat again until the failure is resolved and the appropriate value of

water flow is reached.

Temperature adjustment

Turn the knob to the right to increase the temperature value, or to the left to decrease it.

Push the knob to read the temperature value that is stored in memory. Push it again

to read the next stored value. You can switch between the following settings „SINK”,

„SHOWER” and „BATH”.

To change the temperature setting in memory:

select the temperature setting by pushing the control knob,

push the knob and keep for about 3 seconds until the value starts to flashing,

turn the knob to adjust the value,

push the knob to save the value.

Notice: save the new value within 10 seconds, otherwise you will lose it.

Configuration and parameters view

temperature (min-max) [ S>SET TEMP] –

0

C,

inlet temperature value [S>T INLET] –

0

C,

outlet temperature value [S>T OUTLET] –

0

C,

flow rate [S> FLOW] – l/min,

percentage of maximum power with which the unit currently heats [S> FULL

POW] -%,

work time [S> T – h],

minimum brightness / stand-by-mode [S> BRIGH MIN] [0 - BRIGH MAX],

maximum brightness / active [S> BRIGH MAX] [BRIGH MIN -25],

select language version [S> ENGLISH] (POLSKI, FRANCAIS, ENGLISH,

DEUTCH, РУССКИИ),

software version (PW ........, MSP........).

Push and keep knob for about 5 seconds (until the display backlight turns off) to exit

parameters setting mode.

Notice: parameters setting mode will automatically exit after 5 minutes since the last

adjustment.

Advertising
This manual is related to the following products: