Maintenance

Filter cleaning:

1. Cut off power and cold water supplies.

2. Take off the unit’s cover.

3. Undo the inlet fitting - on the cold water

side.

4. Take the filter out from the inlet fitting.

5. Clean up the filter.

6. Fix the filter back, put the gasket and do

up the inlet fitting.

7. Open the cut-off valve on cold water sup-

ply pipe - check connections for leaks.

8. Fix the unit’s cover back.

10. Vent the water system – see Venting sec-

tion.

Co-operation with other appliances

Unit is equipped with the BLOK and NA clamps.

BLOK – relay input that switches off the slave appliance, the circuit that is connected

to the BLOK clamps (max. 0,1A 250V-) will be opened at the time of heating opera-

tion starts up.

NA – input that locks the unit operation, opened NA contacts locks the heating opera-

tion - co-operation with the master appliance.

Wire (2 x 0,5mm

2

) for BLOCK and NA clamps should be run inside the unit on the

right side.

The wire connections must be performed by a qualified person.