The heater switches on automatically straight after

reaching the flow rate over 2,5 l/min. The temperature

control system adjusts the power rate according to

the water flow rate, required temperature and the

water temperature in the mains.

There are two indicators on the case:

-

green - power supply „on”,

Number of impulses

(red indicator)

the „green” indicator flickering with constant frequency

description

1

the water flow is too high for the temperature setting

2

the unit was switched off by a master appliance

Number of impulses

(green indicator)

the „red” indicator flickering with constant frequency

description

3

the inlet temperature sensor failure

KDE, KDE2 Operation

-

red - heating „on”.

Other modes are shown through these two flickering lights in combination.

KDE

Number of impulses

(green indicator)

description

1

the unit was switched off because the temperature has exceed-

ed the maximum value (fault signal will not disappear until the

appropriate rate of water flow is reached)

2

the unit was switched off by a master appliance

3

the inlet temperature sensor failure

4

the unit was switched off because the air bubbles in the heating

box(the unit will not heat again until the fault is resolved and the

appropriate rate of water flow is reached)