Cleaning

When you are done using your sterilizer, you

need to empty the water from the unit, rinse

thoroughly and dry completely. This procedure

needs to be done daily. Do not leave water in the

unit overnight. Rinse thoroughly between water

changes. Store your sterilizer in a dry area. On

your next use, fill the sterilizer with clean distilled

water. Distilled water is the recommended water.

If distilled water is not available, then you may

use your local water. If your local water supply

contains lime or high levels of minerals, the unit

will require periodic cleaning to remove and

prevent the buildup of deposits.

Units should be cleaned whenever there is a

buildup of lime or mineral deposits. After many

cycles, a white deposit may begin to form on the

bottom of the sterilizer. We recommend cleaning

with a lime remover. Manufacturers of coffee

makers have cleaning solutions which may be

used. There are also solutions available at your

local hardware and drug stores that can be used

to clean aluminum. Follow the manufacturer's

instructions and make up a solution of the

cleaner, filling your sterilizer above the standard

operating level. Let the sterilizer stand a few

minutes then rinse thoroughly. You may have to

repeat this procedure a few times to fully remove

the lime and mineral deposits from your sterilizer.

Never turn the sterilizer "ON" when filled

with a cleaning solution.

You may also use standard white vinegar to clean

your sterilizer. Fill your sterilizer above the

standard operating level with vinegar and let it

stand a few minutes then rinse thoroughly. You

may have to repeat this procedure a few times to

fully remove the lime and mineral deposits from

your sterilizer.

Allowable Operating
Environments

This unit was designed to operate in an indoor

environment between 5° and 40° Celsius or 41°

and 104° Fahrenheit. An allowable pollution

degree per IEC 664 cannot exceed a rating of two.

The allowable relative humidity levels are 80%

for temperatures up to 31°C (88°F) and

decreasing linearly to 50% at 40°C (104°F).

Elevation above sea level.

At altitudes greater than sea level, settings need

to be adequately adjusted to compensate for the

effect of altitude on the boiling point of water. We

suggest you increase pressure by 0.5psi for

every 1000 ft. of elevation above sea level.

City Altitude

Steam Pressure Required

Sea level

15-17 psi

2000ft

16-18 psi

4000ft

17-19 psi

6000ft

18-20 psi

8000ft

19-21 psi

10,000ft

20-22 psi

The power cord supplied with this unit is a 3-

pronged grounded plug. This plug is intended to

be used with a standard 3-prong grounded wall

receptacle to minimize the possibility of electric

shock hazard from this unit. Do not for any

reason cut off the grounding prong or use a 2-

prong adapter plug. This unit is rated to be

operated using local consumer electrical power. It

has a transient over voltage rating of II. The 120V

unit is designed to operate at a frequency of

50/60 Hz with a line of voltage of 115 volts AC+/-

10%. The 240V unit is designed to operate at a

frequency of 50/60 Hz with a line voltage of 230

volts AC +/-5%.

If in doubt, the user should have the wall

receptacle and circuit checked by a

qualified electrician to make sure the

receptacle can provide adequate current

and voltage, and is properly grounded.

Operating Instructions for Model 25X Electric Pressure Steam Sterilizer

IMPORTANT: DO NOT OPERATE THIS PRESSURE STEAM STERILIZER UNTIL YOU HAVE

THOROUGHLY READ THESE OPERATING INSTRUCTIONS.

Geared Steam Gauge

# 72S

Control Valve

#65

Index Alignment Arrow

Overpressure Plug

#1010

Excess Pressure Relief Valve

#2050CS

Air Exhaust Tube