3 error conditions, Error conditions, 6gis – A.O. Smith BFC - 28 User Manual

Page 46

Advertising
background image

Status of the appliance

46

Instruction Manual BFC

6

gis

1) The current time falls within a set time period of the week program.

Figure 6.4

shows the display in this situation:

-

line one: the text

PROG

;

-

line two: the time, the day and alternately T

1

and T

net

. See paragraph

2.3

;

-

line three: the next scheduled switch-off time and the water
temperature T

set

of the active period;

-

line four: is empty, or depending on the heating cycle, a text such as

HEAT DEMAND

. See paragraph

’7.4 The appliance’s heating cycle’

2) The current time falls outside a set time period of the week program.

Figure 6.5

shows the display in this situation:

-

line one: the text

PROG

;

-

line two: the time, the day and alternately T

1

and T

net

. See paragraph

2.3

;

-

line three: the next scheduled switch-on time;

-

line four: the text

PERIOD ACTIVATED

.

In all modes, the temperature may at any moment drop below the desired
temperature. The appliance then enters a heating cycle. This heating cycle is
the same for all basic operating modes. See paragraph

’7.4 The appliance’s

heating cycle’

.

n

Remark

Setting and programming of the basic operating modes are described in
chapter

’8 Main menu’

.

6.3

Error conditions

Figure 6.6

shows an example of an error condition. If the appliance enters this

condition, the display will show the following information:

line one: error code comprising a letter and two digits, followed by the error
description;

lines two through four: alternately, a brief explanation of the error, and a brief
action to resolve the error.

c

Note

The displayed action to resolve the error may only be performed by a
service- and maintenance engineer.

There are various types of errors:

LOCK OUT ERRORS
When the cause is no longer present, these errors require a reset with the
R button, before the appliance can resume running.

BLOCKING ERRORS
These errors disappear automatically once the cause of the error has been
removed, after which the appliance resumes by itself.

The display does not show what type of error has been detected. For a detailed
overview of error conditions, please refer to chapter

’10 Troubleshooting’

.

If, as end-user, you find the appliance in an error condition, you may attempt to
re-start the appliance by pressing the R button once.
However, should the error return or become persistent, you should contact your
service and maintenance engineer.

PROG

10:00 Monday

76ÉC

MO 11:15 Tset 75ÉC

Figure 6.4 week program
active, current time within
programmed period

PROG

12:00 Monday

76ÉC

MO 11:15

PERIOD ACTIVATED

Figure 6.5 week program
active, current time outside
programmed period

S04: SENSOR ERROR

CHECK

SENSOR OR DUMMY

Figure 6.6 Example of an error
message

Advertising