Electrical installation instructions – American Standard 2939 User Manual

Page 27

Advertising
background image

754532-100 Rev. A

27

All wiring must be performed by a licensed electrician in accordance with the national electrical code and all other applicable codes.

WARNING: When using electrical products, basic precautions should always be observed, including the following:

1.

DANGER: RISK OF ELECTRIC SHOCK! Connect only to a circuit protected by a ground-fault circuit interrupter.

2.

Grounding is required. The unit should be installed by a licensed electrician and grounded.

3.

Permit access for servicing motor as noted.

4.

All building materials and wiring should be routed away from the pump body and heater (if equipped).

ELECTRICAL INSTALLATION INSTRUCTIONS

!

ELECTRICAL

FEED

GFCI

120V, 60HZ
15A GFCI

120V, 60HZ
15A GFCI

JUNCTION BOX (CANADA)

GFCI OUTLET (USA)

ELECTRICAL

FEED

AIR SWITCH ACTIVATED WHIRLPOOL PUMP

GFCI

Green/Copper

Black

White

Refer to the schematics below for the appropriate bath electrical installation. Dedicated15A circuits with GFCI (Ground
Fault Circuit Interrupter) protection are required.

At initial start-up with the power ON, push the GFCI test button. The reset button should pop out. Push this button in to
reset. If the GFCI fails to operate in this manner, there is a ground fault or malfunction, indicating the possibility of
electrical shock. Turn of the power and do not use until the source of the problem has been identifed and corrected.