E-z install, Heater – American Standard 2939 User Manual

Page 32

Advertising
background image

32

754532-100 Rev. A

ELECTRICAL INSTALLATION INSTRUCTIONS

(continued)

WHIRLPOOL HEATER OPERATION

Ensure the heater and pump are properly GROUNDED
and BONDED as required. Attach the 8 AWG solid
copper conductor supplied with the heater from the
heater bonding lug to the motor frame bonding lug as
shown in Figure 3.

The conductor is secured to the lugs using set screws.
The motor frame shall have a second 8 AWG solid
copper conductor connected from the frame bonding
lug to the home’s electrical panel or approved local
bonding point as shown in Figure 3.

NOTE: For all “EcoSilent” pump configurations, the
pump housing is plastic. Therefore, the first copper
conductor attached to the heater must be grounded
directly to the home’s electrical panel or approved local
bonding point. this type of configuration does not need
the second copper conductor shown in Figure 3.

RUN 8 AWG SOLID COPPER

CONDUCTORS FROM

HEATER BONDING LUG TO

PUMP/MOTOR FRAME LUG

AND FROM PUMP/MOTOR

LUG TO APPROVED

GROUND AS SHOWN

(PUMP/MOTOR)

TO GROUND

SECOND

COPPER

CONDUCTOR

FIRST COPPER

CONDUCTOR

PUMP/MOTOR FRAME WITH

BONDING LUGS

(NOT ON “ECOSILENT” MODELS)

HEATER ON

E-Z INSTALL

WHIRLPOOL

HEATER

(HEATER)

FIGURE 3: GROUNDING DIAGRAM

FIGURE 4: WHIRLPOOL HEATER

INDICATOR LIGHT

WARNING: Prior to operation, review the Important Safety
Instructions listed at the beginning of this instruction manual.

Once the heater is installed and the whirlpool pump is operating,
the heater is totally automatic. The heater will help maintain the
temperature of the water in the bath.

Pressure Switch

The heater is equipped with a preset pressure switch. The pump
must be running with water flowing in the whirlpool to allow the
heater to turn on.

Indicator Light

This light turns on whenever the heater is operating.

High-Limit Switch

The heater includes an exclusive “Intelligent High-Limit”. This safety circuit will not “false trip” from hot tap water.
It will only turn the heater off if the thermostat fails. If the high-limit trips frequently, call a service technician.
To manually reset the circuit in the event that the “High-Limit” switch has been activated, simply
(1) Turn off the whirlpool pump.
(2) Drain water from the tub.
(3) Remove power from heater by unplugging at receptacle or turning off circuit breaker.
(4) The heater circuit will automatically reset in less than 15 minutes.
(5) Restore power to the heater.
(6) Whirlpool bath is now ready to use.

HEATER “ON” LIGHT

Bonding Lug on
Heater Housing

E-Z INSTALL

WHIRLPOOL

HEATER

FACTORY INSTALLED - NOT FOR RESALE

HEATER P/N: 753174-100

Advertising