6 spin with guard closed, 7 screen-saver time, 8 visual eccentricity check – CEMB USA C218 User Manual User Manual

Page 18: 9 acoustic signal

Advertising
background image

18

Use and maintenance manual Rev. 04-2011

ENGLISH

cing quality. The computer makes a complex calculation
which allows cancelling the residual static unbalance by
varying the value and position of the counterweights of
fixed value.

7.6 SPIN WITH GUARD CLOSED

When “ON” is selected the automatic start of the spin is
enabled when the guard is closed.

7.7 SCREEN-SAVER

TIME

If this function is enabled, the screensaver will automa-
tically be activated when the machine is not used for a
certain period of time. This function can be disabled by
setting it to 0.

7.8 VISUAL ECCENTRICITY CHECK

At the end of wheel acceleration, as soon as the motor is
disengaged, the guard can be opened for visual control
of any wheel eccentricity as the rotation speed gradually
drops. Do not strike the wheel during the entire decelera-
tion stage; to brake the wheel, close the guard. However,
avoid using the brake as far as possible because this may
compromise unbalance measurements. The unbalance
values measured are only displayed when the wheel has
come to a standstill. This function is active for only one
machine run.

7.9 ACOUSTIC SIGNAL

When “ON” is selected, the sending of an acoustic signal
(beep) is enabled in the following cases:

when any push button is pressed;

when dimensions are acquired in automatic mode;

when the correct angular position for weight application

is reached in the Measurement screen;
when the correct angular position for weight application

is reached in the Position Repeater screen.

Setup

Advertising