8.

Special calibrations and functions

In order to gain access to the “Reserved Calibrations and
functions” it is necessary to enter a password.
Any incorrect operation within the functions described
below could impair the operation of the wheel balancing
machine. Unauthorized use will cause cancellation of the
warranty on the machine.

8.1 CONTROL OF ECCENTRICITY

MEASUREMENT

Set to ON/OFF to enable/disenable tyre eccentricity

1.

measurement when starting the unbalance measure

ment

Set the phase shift angle between the eccentricity

2.

measurement sonar and the unbalance correction

point (top vertical, 12.00 o’clock position)

Recommended values: sonar mounted on the guard =
72°.

8.2 PRESETTING THE CUSTOMER AND

USER NAME

The machine can be customized by presetting:
a) The name appearing on the Initial screen (screen-save).
b) The name of 4 different machine users (USER NAME).
An “ideal” keyboard appears on the monitor with the set of
characters available for composition of the wordings.
The Customer’s name consists of three lines, each max. 30
characters. The USER NAME consists of a wording max. 15
characters.

8.3 CALIBRATIONS

When

is pressed from the Special Functions menu,

access is gained to the Calibration menu.

8.3.1 Gauge calibration

8.3.1.1 Distance gauge calibration

To calibrate the distance gauge, set it in rest position and
then on the adapter plane.
When done, set the gauge in rest position. If calibration is
correct, the wheel balancer is ready for operation, otherwise
an error message may be displayed if there are errors or
malfunctioning; in this case repeat calibration.

to cancel the distance gauge calibration

function if has erroneously been accessed.

Special calibrations and functions

8.3.1.2 Diameter gauge calibration

To calibrate the diameter gauge, place it on the adapter

fl ange and press

. For better calibration turn the gauge

downward and position it 40 mm away from the adapter plane.
On the screen a value is shown near the word POS: if it is
256+/- 3°, set the gauge to rest position, otherwise press

.

to cancel the diameter gauge calibration function

if it has erroneously been accessed.

8.3.2 Balancing machine calibration

To calibrate the balancing machine, use a wheel with steel
rim of average dimensions, e.g. 6” x 14” (±1”).

To properly perform the procedure:

Mount a wheel on the machine, even unbalanced, and

very carefully set its dimensions.

INDICATION

Setting incorrect measurements will result in the machine

not being correctly calibrated, and balancing of subse-

quent wheels will hence be incorrect until the machine is

recalibrated with the correct measurements!!

Follow the on-screen instructions.

8.4 WHEEL BALANCING MACHINE SELF

TEST

An automatic self-diagnostic cycle is provided for easier
trouble-shooting (

Consult the extraordinary mainte-

nance manual or contact Technical Service).