5 automatic gauges calibration, 1 rim distance gauge, 2 diameter gauge – CEMB USA ER80 (C) User Manual

Page 17

Advertising
background image

17

Flange plane

Use and maintenance manual Rev. 04-2012

ENGLISH

Close the guard to perform a spin.

2. Add a standard weight of 60 g (2.00 oz) to the outer

side, in any position.

.

Close the guard to perform a spin.

3. Shift the standard weight from the outside to the

inside keeping the same position.

Close the guard to perform a spin.

4. Turn the wheel until the standard weight is at the top

(12 o’clock).

5. Turn the wheel until the sample weight is in

correspondence to the centre-line of the weight clip.

Pressing the button

a default value is set.

Turn the wheel until the centre-line of the sample weight
is in correspondence to the laser beam.

Pressing the button

a default value is set.

6. End of calibration.

To cancel calibration at any time, press

.

6.5

AUTOMATIC GAUGES CALIBRATION

6.5.1 Rim distance gauge

Display the SETUP menu

1. Press

/

to view the rim distance

gauge CALIBRATION function.

2. Leave the distance gauge in rest position and press

4. Move the distance gauge pusher in line with the

adapter

surface and press

CALIBRATION COMPLETE
Return the gauge to rest position.
The wheel balancer is ready for operation.

INdIcATIoN

In the event of errors or faulty operation, the writing

r.P.:

ap

pears on the display : shift the gauge to the

rest position and repeat the calibration operation exactly
as described above. If the error persists, contact the
Technical Service Department. In the event of incorrect
input in the rim distance gauge calibration function, press

to cancel it.