Err. 22

Maximum number of spins
possible for the unbalance
measurement has been exceeded.

1. Check that a vehicle wheel has been mounted on the wheel

balancer.

2. Check functioning of the phase encoder and, in particular, the

reset signal.

3. Replace the computer board.

Err.24

Distance between the spokes
less than 18 degrees.

1. The minimum distance between the spokes where the

unbalance is to be split must be greater than 18 degrees.

2. Repeat the SPLIT function increasing the distance between

the spokes.

Err.25

Distance between the spokes
greater than 120 degrees.

1. The maximum distance between the spokes where the

unbalance is to be split must be less than 120 degrees.

2. Repeat the split function increasing the distance between the
spokes.

Err.26

First spoke too far from the
unbalance

1. The maximum

distance

between the unbalance position and

the spoke must be less than 120 degrees.

2. Repeat the split function increasing the distance between the
spokes and the unbalance.

Unbalance
incorrect
with back
centring
cones

Wheel slipping on the adapter
because the BP system is at
the end of travel or because of

incorrect fitting of the tyre tie-rod

Mount the wheel in vertical position and push the sleeve up

against the wheel. If necessary, repeat locking/unlocking/locking
and perform the procedure again.