16

Use and maintenance manual Rev. 01-2010

ENGLISH

6.5

CALIBRATION

To calibrate the machine, proceed as follows:

Fit an average size wheel with a metal rim on the shaft.

Example: 6” x 15” (± 1”).
Set the wheel measurements as described in paragraph

USE OF THE WHEEL BALANCER.

CAUTION

S

ETTING

INCORRECT

DIMENSIONS

WOULD

MEAN

THAT

THE

MACHINE

IS

NOT

CORRECTLY

CALIBRATED

, T

HEREFORE

,

ALL

SUBSEQUENT

MEASUREMENTS

WILL

BE

INCORRECT

UNTIL

CALIBRATION

IS

PER

-

FORMED

ONCE

AGAIN

WITH

THE

CORRECT

DIMENSIONS

.

Display the SETUP menu:

P

1. ress

to view the CALIBRATION

function.

A

2. dd a standard weight of 60 g (2.00 oz) to the outer

side, in any position.

.

Sh

3.

ift the standard weight from the outside to the

inside keeping the same position.

Tu

4.

rn the wheel until the standard weight is at the top

(12

o’clock).

End of calibration.

5.

To cancel calibration at any time, press

.

6.6

AUTOMATIC GAUGES CALIBRATION

6.6.1 Rim distance gauge

Display the SETUP menu

P

1. ress

to view the rim distance

gauge CALIBRATION function.

Leave the distance gauge in rest position and press

2.

Br

3.

ing the gauge in line with the adapter flange and

press

CORRECT CALIBRATION
Return the gauge to rest position.
The wheel balancer is ready for operation.

INDICATION

In the event of errors or faulty operation, the writing

r.P.:

ap

pears on the display : shift the gauge to the

rest position and repeat the calibration operation exactly
as described above. If the error persists, contact the
Technical Service Department. In the event of incorrect
input in the rim distance gauge calibration function, press

to cancel it.