6.6.2 Diameter gauge

E

Display the SETUP menu

P

1. ress

to view the diameter

gauge CALIBRATION function.

m

Place the round part of the gauge terminal on the

flange as shown in the figure and press

Th

2.

e number 354 ± 3° appears on the left display .

Turn

3.

the gauge downward position the round part

of the gauge terminal at 40 mm (radial distance)

from the flange as indicated in the figure; alternati

vely use one of the cones provided as shown in the

images

The nu

4.

mber 254 ± 3° should appear on the left

display. The calibration is already correct.

If not, press the

button holding the gauge still at 40

mm: the number 254 appears on the left display.
Return the gauge to rest position.

6.6.3 Width sonar (option)

Display the SETUP menu

P

1. ress

to view the width sonar

CALIBRATION

function.

Set with

2.

the distance in mm betwe

en the Sonar sensor (0 sonar) and t

he end of the

distance gauge (at rest).

A = Distance: Gauge at rest to

0 sonar

In the event of incorrect input in the width gauge calibration

function, press

to cancel it.