Sa series feature string nomenclature, 14 feature 9: refrigeration accessories, Feature 10: power options – AAON SA-070 User Manual

Page 14: Feature 11: safety options, Feature 12: controls, Feature 13: special controls

Advertising
background image

SA Series Feature String Nomenclature

GEN

S

IZ

E

V

L

T

C

ON

FIG

A1

A2

A3

A4

B1

B2

B3

1A

1B

1C

1D

2

3

4

5A

5B

5C

6A

6B

6C

7

8

9

10

11

12

13

14A

14B

15

SA - 035 - 3 - A - E R 0 9

-

0 0 0

:

A C 0 0 - 0 0 0 - E B F - A B 0

-

0 0

0 0 0 0 0 - H

A - 0

0 0 0 0 0 0 0 B

16

17

18

19

20

21

22

23

14

Feature 9: REFRIGERATION
ACCESSORIES

0 = Standard
A = Sight Glass
B = Compressor Isolation Valves
C = Options A + B


Feature 10: POWER OPTIONS

0 = Standard Power Block

Feature 11: SAFETY OPTIONS

0 = Standard
A = Supply Air Smoke Detector
H = Remote Smoke Detector Terminals

Feature 12: CONTROLS

0 = Standard
A = Low Limit Controls
B = Phase and Brown Out Protection
C = Options A + B

Feature 13: SPECIAL CONTROLS

0 = Terminal Block for Thermostat Control
A = VAV Unit Controller - VAV Cool + CV Heat
B = Constant Volume Unit Controller - CV Cool +

CV Heat

C = Make Up Air Unit Controller - CV Cool + CV

Heat

L = Terminal Block for Thermostat Control with

Isolation Relays

Y = VAV Single Zone Heat Pump Unit Controller -

VAV Cool + VAV Heat

Z = Constant Volume Heat Pump Unit Controller -

CV Cool + CV Heat

1 = Make Up Air Heat Pump Unit Controller - CV

Cool + CV Heat

2 = VAV Single Zone Unit Controller - VAV Cool +

CV Heat

3 = VAV Single Zone Unit Controller - VAV Cool +

VAV Heat

4 = Field Installed DDC Controls by Others
5 = Field Installed DDC Controls by Others with

Isolation Relays

6 = Factory Installed DDC Controls Furnished by

Others with Isolation Relay

Feature 14: WATER-COOLED
CONDENSER AND WATERSIDE
ECONOMIZER

14A: WATER-COOLED CONDENSER
0 = Standard - None
A = Balancing Valves
B = Water Flow Switch
C = Motorized Shut-Off Valve
D = Head Pressure Control
E = Options A + B
F = Options A + C
G = Options A + D
H = Options B + C
J = Options B + D
L = Options A + B + C
M = Options A + B + D
S = Option A + SMO 254 Corrosion Resistant

Brazed Plate Condenser

T = Option B + SMO 254 Corrosion Resistant

Brazed Plate

U = Option C + SMO 254 Corrosion Resistant

Brazed Plate

V = Option D + SMO 254 Corrosion Resistant

Brazed Plate

W = Option A + B + SMO 254 Corrosion Resistant

Brazed Plate

Y = Option A + C + SMO 254 Corrosion Resistant

Brazed Plate

Z = Option A + D + SMO 254 Corrosion Resistant

Brazed Plate

1 = Option B + C + SMO 254 Corrosion Resistant

Brazed Plate

2 = Option B + D + SMO 254 Corrosion Resistant

Brazed Plate

3 = Option C + D + SMO 254 Corrosion Resistant

Brazed Plate

4 = Option A + B + C + SMO 254 Corrosion

Resistant Brazed Plate

5 = Option A + B + D + SMO 254 Corrosion

Resistant Brazed Plate





Advertising
This manual is related to the following products: