Optical flange focal distance, C-mount cross section, Ge36 – ALLIED Vision Technologies Prosilica GE4900 User Manual

Page 36

Advertising
background image

Prosilica GE Technical Manual V2.0.3

36

Camera dimensions

Optical flange focal distance

Optical flange focal distance is the optical distance from the mounting flange to
the image sensor die (see figure 24 and figure 25). Optical flange focal distance
can be calculated as:

C-Mount cross section

Table 13 presents flange focal distance and maximum lens protrusion values for
Prosilica GE cameras with C-Mount.

Figure 24: Cross section of typical Prosilica GE front assembly with C-Mount

Camera Lens protrusion [mm] IR cut filter* [mm] Sensor window [mm]

Nominal flange focal

distance [mm]

GE680

13.64

-

0.84

17.81

GE680C

9.01

1.00

0.84

18.14

GE1050

13.64

-

0.76

17.78

GE1050C

9.71

1.00

0.76

18.11

GE1650

13.64

-

0.76

17.78

GE1650C

9.20

1.00

0.76

18.11

GE1660

13.64

-

0.76

17.78

Table 13: Flange focal distance and maximum lens protrusion for Prosilica GE cameras with C-Mount

Optical flange focal distance Flange focal distance

IR cut filter thickness

Sensor window thickness

+

3

-------------------------------------------------------------------------------------------------------------

Flange focal distance

Max. lens protrusion

IR cut filter thickness

Sensor window thickness

Section A-A

A

A

Image sensor die

Advertising