Analog Way Smart Edge User Manual

Page 17

Advertising
background image

15

Dimensions:

W 482 x D 330 x H 45 mm

19”W x 13,8”D x 1,8”H

Weight:

4,3 kg / 9,5 lbs

(Compatible with a Standard 19” rack, Height = 1 U)

Cooling air flow from right side to left side.

Max ambient operating temperature:

< 40°C (< 104°F).

Operating temperature:

0 to +40°C / +32°F to +104°F

Storage temperature:

-40 to +70°C / -40°F to +158°F

Operating humidity:

10 to 80% (non condensing)

Input voltage range:

100-240 VAC, 50/60 Hz

Typical consumption:

90 W

CE Compliancy, test following:

- EN 55022: 2006 / A1: 2007,

- EN 55024: 1998 / A1: 2001 / A2: 2003,

- EN 61000-3-2: 2006,

- EN 61000-3-3: 1995 / A1: 2001 / A2: 2005.

Safety, test following:

- IEC 60950-1: 2005,

- UL 60950-1: 2007,

- CAN/CSA-C22.2 NO. 60950-1.

Power supply: IEC/EN/UL/CSA 60950-1, internal, autoswitching

Mechanical (in carton): Vibration: IEC60068-2-64

Free fall: IEC60068-2-32, RoHS, WEEE

Communication specifications

Environmental specifications

• COMMUNICATION PORTS

REMOTE RS232

Connector:

DB 9 female.

Protocol:

RS-232.

Data Rate:

9600 Bauds, 8 data bits, 1 stop bit, no parity bit, no flow control

by

default.

DTR & RTS needed for upgrade.

• LAN

Connector:

RJ45.

Protocol:

TCP (Transmission Control Protocol) or UDP

(User Datagram Protocol).

Ethernet:

Base 10/100.

Advertising