7. Power On


7.1. Operating Mode

After power on the absolute rotary encoder
sends two times his MAC ID telegram on the
bus.

7.2. Programming

If some parameters should not be modified
you can skip over this chapter.
The following numbers are given in hexadeci-
mal

format. In the examples, the CAN ID and MAC
ID are 0A (hex) and for the slave 03 (hex).
The changeable values are written in an ital-
ics.

7.2.1. Operating Parameter
Master to absolute rotary encoder: Set-Parameter

CAN ID

MAC ID

Service

Code

Class

ID

Instance

ID

Attribute

ID

Data

Byte 0

Byte1

Byte 2

Byte 3

Byte 4

Byte 5 Byte 6 Byte 7

41C

0A

10

23

01

70

X

-

-

X: 1 hex for CW (Default)

0 hex for CCW


Absolute Rotary Encoder to Master:Confirmation

CAN ID

MAC ID

Service Code

Byte 0

Byte 1

41B

0A

90

7.2.2. Resolution per revolution

Master to Absolute Rotary Encoder:Set-Parameter

CAN ID

MAC ID

Service
Code

Class
ID

In-
stance
ID

Attribute
ID

Data

Byte 0

Byte 1

Byte 2

Byte 3

Byte 4

Byte 5

Byte 6

Byte 7

41C

0A

10

23

01

71

X

X

-

X: desired resolution per revolution

Page 14