3.1.3. Total resolution

This value is used to program the desired num-
ber of measuring steps over the total measur-
ing range. This value must not exceed the total
resolution of the encoder with 24 bit =
16,777,216 steps

(25 bit = 33,554,432 steps). Please note the
value written on the type shield.

Attribute ID

Default value Value range

Data Type

72 hex

(*)

0h - 2,000,000h

Unsigned Integer 32


(*) see type shield
Maximum total resolution
24 Bit Encoder: 1,000,000 hex
25 Bit Encoder: 2,000,000 hex

Attention:
The following formula letters will be used:
-

PGA Physical total resolution of the en-

coder (see type shield)

-

PAU Physical resolution per revolution

(see type shield)

-

GA Total

resolution

(customer

parame-

ter)

-

AU

Resolution per revolution (customer
parameter)


If the desired resolution per revolution is less
than the physical resolution per revolution of
the encoder, then the total resolution must be
entered as follows:

Total resolution
GA = PGA * AU / PAU, if AU < PAU
Example: Customer requirement: AU = 2048,

Encoder type shield: PGA=24 bit, PAU=12 bit

GA = 16777216 * 2048 / 4096

GA = 8388608


If the total resolution of the encoder is less than
the physical total resolution, the parameter
total resolution must be a multiple of the
physical total resolution:
-

k = PGA / GA

-

k = integer



3.1.4. Preset value

The preset value is the desired position value,
which should be reached at a certain physical
position of the axis. The position value of the


encoder is set to the desired process value by
the parameter preset. The preset value must
not exceed the parameter total measuring
units

Attribute ID

Default
value

Value range

Data Type

73 hex

0 hex

0hex - total measuring
range

Unsigned Integer 32

Version 05/04

UME-OCD-D2