Datamax-O'Neil DPL Programmer’s Manual User Manual

Page 12

Advertising
background image

Overview

4

Configuration Commands

The following table lists some commands useful in controlling printer configuration.
These commands are generally effective only for the current power-up session; toggling
power restores the default configuration. See <STX>Kc for changes to the default power-
up configuration. Changing the default power-up configuration and saving objects in
printer Flash memory can reduce the data transmitted for each label and therefore

improve throughput.

Configuration

Command

Name

Function

<STX>A

Set Date and Time

Sets Date and Time.

<STX>c

Set Continuous Paper Length Must be 0000 for gap media; not used

for reflective media.

<STX>e

Set Edge Sensor

Sets sensing for gap or registration hole

type stock.

<STX>Kf

Set Present Distance

Determines label stop position, head
relative. <STX>f edge sensor relative
equivalent command, older models.

<STX>Kc

Configuration Set

Determines default power-up

configuration.

<STX>F

Send Form Feed

Sets the stop position of the printed

label.

<STX>M

Set Maximum Label Length

Length to search for next gap or
reflective mark; not used with

continuous media.

<STX>m

Set to Metric Mode

Subsequent measurements interpreted

in metric (most units, mm/10). Label

equivalent command can be used.

<STX>n

Set to Inch Mode

Subsequent measurements interpreted

in inches (most units in/100) label
equivalent command can be used.

<STX>S

Set Feed Rate

Sets blank label movement speed.

<STX>V

Software Switch

Enables optional hardware, cutter, and
present sensor.



Download Commands

Download

Command

Name

Function

<STX>I

Download Image

Downloads Image to selected memory

module.

<STX>i

Download Scalable Font

Downloads Scalable Font to selected

memory module.

<ESC>

Download Bitmapped Font

Downloads Bitmapped Font to selected

memory module.


Advertising
This manual is related to the following products: