<STX>Kc
Parameter Name
Parameter
Pneumonic
Value /
Range
Units /
Interpretation
Command
Equivalent
Empty Sensor Level
EV
0 – 255
N/A
N/A
End Character
EN
D
N/A
N/A
End Of Print
EP
1, 2, 3, 4
1 = Low Pulse,
2 = High Pulse,
3 = Active Low,
4 = Active High
N/A
ESC Sequences
ES
Y, N
Y = Enabled,
N = Disabled
N/A
Fault Handling
FH
L, D, R, B
See Command
N/A
Feed Speed
SS or sS
Alpha character
Model specific ranges;
see Appendix L.
Sa
Feedback Mode
FM
Y, N
Y = Enabled,
N = Disabled
<STX>a