Replacing the Platen Roller
Note:
Inspect your printer and determine if the Platen Roller Assembly installed in 
your printer includes the Integral Gear as shown to the left. If the Integral 
Gear is present it is not necessary to replace the Platen Roller Assembly, 
proceed to ‘Installing the Peel and Present Assembly’ 
Integral
Gear
 
 
 
 
 
 
 Remove the Sensor Cover by pulling it from the 
printer in the direction of the arrows, as shown. 
(If equipped with the optional Present Sensor, 
first disconnect the cabling to the Options 
Connector). 
 Note: If necessary, the Front Panel can be loosened to facilitate the removal of the Sensor Cover.
 
 
 Remove the two Screws securing 
the Bearing Plate then remove 
the Bearing Plate. 
 
 Remove the Platen Roller 
Assembly.
Reassembly
 
 Place the Outside Bearing onto the Platen Roller Assembly. 
 
 Using care to avoid the Platen Roller, place a very small amount of silicon grease on the Compound 
Gear.
 
 Position the new Platen Roller Assembly in the printer. 
 
 Position the Bearing Plate onto the printer and secure with the two Screws. 
 
 Position the Sensor Cover. Then rotate the cover inward until it snaps into place. 
 