62

I-Class

Three samples are required:

Empty: Nothing in the sensor.

Gap (or Mark): The media liner, notch, or reflective mark in the sensor.

Paper: The label (and liner, if any) in the sensor.



With the correct SENSOR TYPE selected (see Section 4.2.2), perform a Standard Calibration

as follows:

Step

Action

Displayed Message

Comment

1

Turn ON the printer.

UNCALIBRATED

Wait briefly, about six

seconds, for the printer
to initialize.

2

Press the

Key, and

then raise the printhead

assembly.

MENU MODE

MEDIA SETTINGS

You are in MENU MODE.

3

Press the

Key.

MEDIA SETTINGS

MEDIA TYPE

You are in MEDIA

SETTINGS.

4

Press the

Key then

scroll to SENSOR
CALIBRATION.

MEDIA SETTINGS

SENSOR CALIBRATION

Press the

Key to

cancel this procedure.

5

Press the

Key.

SENSOR CALIBRATION

PERFORM CALIBRATION

You are beginning the

procedure.

6

Press the

Key, and

then press any key.

REMOVE LABEL STOCK

PRESS ANY KEY <yyy>

No media should be in
the sensor. This sets the

Empty value, where
“yyy” is the current
sensor reading.