29

DC POWER SUPPLY CONNECTIONS

The DFX may be operated from a 12-28 VDC source, as long as the source is capable of supplying 7 Watts.

12 VDC Supply @ 600 mA minimum

24 VDC Supply @ 300 mA minimum

1) Verify that the jumpers are properly placed. See the wiring diagram located on the inside door of

the DFX enclosure or see Figure 3.4. The jumpers at JP3 should not be present and the jumpers at
JP1 and JP2 will be in place.

2) Connect the DC power source as illustrated in the schematic in Figure 3.6. Wire up to 14 AWG can

be accommodated in the DFX terminal blocks.

a) A switch or circuit breaker is required in the installation.
b) The switch or circuit breaker must be in close proximity of the DFX and within easy reach

of the operator.

c) The switch or circuit breaker must be marked as the disconnect device for the DFX.