ɕɕ ɕ, Clock thermostat and wall-mounting receiver, Inserting or re-inserting the batteries – DE DIETRICH AD248 thermostat User Manual

Page 5: Setting to current time and day, Temperature setting, Programming, Product presentation, Fr gb de it es, ቢባ ቤ ብ

Advertising
background image

Inserting or re-inserting the batteries

Thermostat is equipped with a warning light to indicate when the batteries need replacing. As soon as
this indicator lights up at the bottom right-hand side of the display panel, replace the batteries (use two
1.5V LR6 alkaline batteries - life is approximately 12 months).
Thermostat remains programmed for 60 seconds while batteries are being replaced.

!

Before beginning the programming of the device, please slide cover down and press

RESET

with the tip of a pen.

Setting to current time and day

You are putting the device into operation for the first time.You have just pressed the

RESET

button (see

above). 1122::0

000 appears and the pointer

flashes under day 1.

Set the time using the

+

or

buttons (the

numbers run off more quickly when the
button is pressed continuously).

Set the current day by pressing several times on
the

DAYS 1-7

button. A pointer

appears

under the corresponding day (1=Monday,
2=Tuesday, 3=Wednesday, etc.).

Validate with

OK

button.

If you wish to change the time or the day,
press the

MODE

button until the pointer

appears under the clock sign and continue as
above for points

,

and

.

Temperature setting

Comfort and reduced temperatures are pre-set:
comfort = 20°C,
reduced = 16°C.
Modification of comfort temperature

Press the

.button.

Modify the temperature with the

+

or

button.

Validate with

OK

button.

DAYS

1-7

PROG

P1-P4

0000

h

DAYS

1-7

PROG

P1-P4

0000

h

Modification of reduced temperature

Press the

.button.

Modify the temperature with the

+

or

button.

Validate with

OK

button.

Programming

You can program your week according to 4
program settings: P1, P2, P3 are prerecorded and
cannot be modified.
P4 : is blank and allows you to create a personalized
program varying according to the day of the week.

P1 = Comfort temperature from 6 a.m. till 11 p.m.

Reduced temperature from 11 p.m. till 6 a.m.

The default allocation of P1 is to 7 days of the week.
If this corresponds to your life style, stay in automatic
mode. Otherwise, continue.

P2 = Comfort temperature from 6 a.m. till 8.30

a.m. and from 4.30 a.m. till 11 p.m.
Reduced temperature from 8.30 p.m. till 4.30
a.m.

and from 11 p.m. till 6 a.m.

P3 =

Comfort temperature from 6 a.m. till 8.30
p.m.
from 11.30 a.m. till 1.30 p.m. and from
4.30 p.m. till 11 p.m.
Reduced temperature from 8.30 a.m. till
11.30 a.m. from 1.30 p.m. till 4.30 p.m. and
from 11 p.m. till 6 a.m.

P4 = Blank program allowing you to create up to

12 comfort temperature periods and 12

reduced periods for each day of the week.

Selection of an existing P1, P2 or P3
programme for a day of the week
(in program-
ming mode all modifications are automatically
validated).
Example - P2 for Wednesday.

Press the

PROG P1-P4

button to go into

programming mode.
The n° of the program assigned to the day
flashes on the right-hand side of the display
panel.

Press the

DAYS 1-7

until the pointer

appears under the day you wish to program
(Wednesday in our example).

Press the

PROG P1-P4

button until the P2

program number flashes in the right side of the
screen.

Press the

OK

button to validate. The following

day is automatically proposed.

DAYS

1-7

PROG

P1-P4

0000

h

DAYS

1-7

PROG

P1-P4

0000

h

Auto Manu

1

2

3

4

5

6

7

°

c

°

c

+

-

OK

PROG
P1-P4

DAYS

1-7

MODE

Res

Clock thermostat and
Wall-mounting receiver

ref. 56278

Programmable clock thermostat
and 1 channel 433 MHz receiver

9

4

1

6

-0

9

5

-0

0

/0

1

.0

9

Digital programmable clock thermostat, weekly
cycle and 1 channel 433 MHz receiver, 1 contact
16A AC1, free of potential

Product presentation

Thermostat has been designed to offer you comfort

and energy savings. It allows you to program and
adjust your heating according to 3 temperature
levels:

Comfort temperature: this is the temperature for

your hours of presence.

Reduced temperature: this is the temperature for

your brief absences or during the night.

Frost-protection temperature: this is the minimum

temperature for long absences. It protects your
dwelling from the risk of frost.

These 3 prerecorded programs and a blank program

will allow you to adapt your heating each day to your life
style.
This instruction leaflet introduces you to the different
functions of thermostat.

0

1

2

3

4

5

6

7

8

9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

Auto Manu

1

2

3

4

5

6

7

°

c

°

c

°

c

OK

PROG
P1-P4

DAYS

1-7

MODE

Res

timer

days

+/– buttons for

adjusting settings

Ambiante

temperature

Warning light

to indicate

battery wear

Prolonged

absence

(holidays)

Comfort

temperature

setting

Reduced

temperature

setting

Validation

Reset

Comfort

temperature

Reduced

temperature

P1 to P4

programme

selection

Viewing of

comfort and

Reduced

period

Pointer

indicating day

of the week

Heating

start-up

indicator

Mode

selection

Days of the

week selection

(1=Monday, 2=Tuesday....

7=Sunday

Indicator for

current

temperature level

Comfort

or Reduced

-

+

ɕ

ɕ

ɕ

ɕ ɕ

FR

GB

DE

IT

ES

Auto Manu

1

2

3

4

5

6

7

+

-

MODE

OK

PROG
P1-P4

DAYS

1-7

MODE

Res

Auto Manu

1

2

3

4

5

6

7

°

c

°

c

+

-

OK

PROG
P1-P4

DAYS

1-7

MODE

Res

Auto M

anu

1

2

3

4

5

6

7

°

c

°

c

+

-

OK

PROG

P1-P4

DAYS

1-7

MODE

Res

0

1

2

3

4

5

6

7

8

9

10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

Auto Manu

1

2

3

4

5

6

7

°c

°c

°c

+

-

MODE

OK

PROG
P1-P4

DAYS

1-7

MODE

0000

h

Res

timer
days

Auto M

anu

1

2

3

4

5

6

7

°

c

°

c

+

-

OK

PROG

P1-P4

DAYS

1-7

MODE

Res

0

1

2

3

4

5

6

7

8

9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

0

1

2

3

4

5

6

7

8

9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

0

1

2

3

4

5

6

7

8

9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

0

1

2

3

4

5

6

7

8

9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

Auto Manu

1

2

3

4

5

6

7

°

c

°

c

°

c

OK

PROG
P1-P4

DAYS

1-7

MODE

timer

days

-

+

Res

5

Advertising