Wall-mounting receiver

ref. 56278

1 channel 433 MHz receiver,
1 contact 16A AC1

1 channel 433 MHz receiver,1 contact 16A AC1,
free of potential

The radio receiver is designed to operate with

thermostats and programmable room thermostats
and used to control a boiler or an electric heater.

ɕ

ɕ

ɕ

ɕ ɕ

FR

GB

DE

IT

ES

Product presentation

ቢ Push button for configuration and priority

setting.

ባ Indicator of Power on and coding light.

LED on = product is powered on.
This LED flickers during coding operations.

ቤ Operation indicator light.

The LED is on when receiver’s output contact
is closed = ON.

!

The transmitter and receiver assembly is factory
coded and is therefore immediately operational.

Configuration

In order to associate the transmitter with the receiver:
• Press the receiver’s ቢ push button for more than

3 seconds.

• The indicator

OK

ባ light will start flickering,

release the push button.
The system is in configuration mode.

• Press the RESET button during 3 seconds of the

transmitter.

• The indicator

OK

ባ button will stop flickering,

at the end of 5 secondes.
The transmitter/receiver link is now established.

Reset

For clearing all transmission/reception links:
• Press the receiver’s push button ቢ for more

than 10 seconds.

• The indicator

OK

ባ light flickers slowly, then

more quickly.

• Press again the receiver’s push button ቢ more

than 3 seconds.

• The indicator

OK

ባ light stops flickering, all links

have been cleared.
The receiver returns to the auto mode.

Priority setting

Manual control is provided for this product.
• Press shortly receiver’s ቢ push button (<3

sec).

Each press reverses output state.

!

Radio control retains priority.

Troubleshootings

The heating does not start:

- receiver’s power supply is cut off (

OK

ባ light is

off). Check fuse and circuit breaker.

Receiver is outside of transmitter’s

range:
- move transmitter closer to receiver.

Receiver does not recognize transmitter’s

code:
- re-install receiver.

The system does not start or does not stop:

- the receiver or transmitter is disturbed

by radio transmission (radio ham, TV monitor,
cellular phone re-transmitter, etc.): attempt to
remove the source of disturbance.

In case of persistent problem,call on your elec-
trician.

Technical specifications

Supply voltage:

230 V +10 % at -15 %

Minimum load:

12 V 100 mA

Output:

1 changeover contact free of potential

Switching capacity:

AC1: 16 A 250 V

Inductive: 3 A (cos

ϕ = 0,6)

Radio frequency:

433.92 MHz

Degree of protection:

IP43

Isolation class:

II

Mechanical protection:

IK04

Operating temperature:

-10°C to +60°C

Storage temperature:

-20°C to +70°C

Electrical connection

Flexible capacity: 0,5 to 1,5 mm

2

Rigid capacity 0,5 to 2,5 mm

2

Dimensions:

130 x 60 x 27 mm

Hygrometry:

90% max. at 20°C

Receiver class :

2

Made in France
Usable in all Europe and Switzerland

Installation

!

Before working on the installation, isolate all
electrical supplies. All electrical wiring must
be carried out by a qualified person.

For easier installation, the kit is suppplied with a
flexible 4-wire 1,5 mm

2

cable of 1.20m length (not

connected).
We recommend using this cable for connecting the
HF receiver according to the following colour
codes:

brown = phase
blue = neutral
gray

}

= connection to the boiler

black

5 4 3

1

N

L

2

N

L

N

L

5 4 3

2

1

L

N

5 4 3

1

N

L

2

N

L

N

L

5 4 3

2

1

L

N