EN

4. Prior to first use

4.1 Setting language, time and date

The menu for selecting the language (international version) or setting the time (Dutch version)

appears when you connect the thermostat.

1. Select the desired language if applicable by turning button C and then push button C to confirm.

2. Follow the instructions on the display to select the time, year, month and day.

The thermostat is now ready for use. After installation, the default program is activated

(see paragraph 4.2). The temperature is now controlled by this clock program.

i

The thermostat automatically switches between summer time and winter time settings.

4.2 Default setting
Room control
The thermostat is set to room control by default. This means that the flow temperature of the

central heating water is controlled by the temperature in the room where the thermostat is installed.

Weather-compensated boiler control is also possible (with outside sensor); in other words based on

the outside temperature. The thermostat has a programmed heating curve which determines the

water flow temperature together with the outside temperature. The heating curve must be chosen

so that the least favourable room can be efficiently heated even when the outside temperature is

very low.

See paragraph 5.5 for further information about weather-compensated control.