DE DIETRICH Thermostat modulant d’ambiance User Manual

Page 62

Advertising
background image

62

EN

Heating curve – an example

-5

-15

5

15

25

Outside temperature (ºC)

Boiler temperature (ºC)

100

90
80
70
60
50
40
30
20
10

0

0

Base point

T001032-06-A

Climate point

Desired room temperature

of 15ºC during the night

Increased room temperature

during the day

Desired room temperature

of 20ºC during the day

i

See also see day/night temperature limit 12.4

The settings for the heating curve are highly dependent on the design of the central heating

system and the home. This means that no clear advice can be given on this matter. The heating

curve can be optimised during use. The heating curve also shifts upwards or downwards when

the temperature is increased or decreased.