1setting the load pump timer, 1instelling van de tijdvertraging van de laadpomp – DE DIETRICH МВ 2 User Manual

Page 6

Advertising
background image

6

AD128

25/08/09 - 94866509 - 8801-4297E

N

8801

11

8A

SB

L N

T

Mini

Maxi

T=0

TEMPO

1

2

3

1

Setting the load pump timer

Nederlands

De module MB2 zorgt voor de regeling van de temperatuur en de
voorrang van de productie van sanitair warm water.

1

Instelling van de tijdvertraging van de

laadpomp

1. Timer activated

2. Timer setting deleted

3. Timer setting

The load pump timer setting enables load pump operation for 4
minutes (factory setting) after burner shutdown. This makes it
possible to use the residual heat accumulated in the heating body to
back up tank heating in summer.
The timer setting can be adjusted from 3 to 6 minutes using the
potentiometer located on the back of the appliance.
To delete the timer setting, move the bridge located on the back of the
appliance.

1. Tijdvertraging ingeschakeld

2. Tijdvertraging opgeheven

3. Instelling tijdvertraging

De tijdvertraging van de laadpomp laat de werking van de laadpomp
gedurende 4 minuten (standaard instelling) toe na uitschakeling van
de brander. Op die manier kan de in het verwarmingslichaam
opgehoopte restwarmte gebruikt worden ter aanvulling van het
opwarmen van de boiler in de zomer.
De tijdschakeling is in te stellen tussen 3 en 6 minuten, met behulp
van de potentiometer op de achterzijde van het apparaat.
Om de tijdvertraging op te heffen moet de brug op de achterzijde van
het apparaat verplaatst worden.

English

The MB2 module handles temperature regulation and domestic hot
water production priority.

Advertising