3 parameter display - diemasol a solar regulator – DE DIETRICH SOLNEO SGC 24 SOL User Manual

Page 7

Advertising
background image

7

15/10/2009 - 300017555-001-C

SGC 24 SOL

3. Description

3.3 Parameter display - Diemasol A solar regulator

`

To scroll the parameters, push on key < or >.

T

6-position switch

-

.

: Shutdown/antifreeze/vent.

-



: Domestic hot water (Summer).

-

"

: Heating and domestic hot water (Winter).

-

V

: Measurement mode (Key to access the parameters reserved for the installer).

-

K

: Fitter mode (Key to access the parameters reserved for the installer).

-

M

: Sweeping mode (Key to access the parameters reserved for the installer).

U

"Heating" on light

The light is on when the heating/domestic hot water reversal valve is in the heating position and the
circulator pump is operating.

V

Heating temperature setting

Adjustment range : 30 °C to 90 °C (Hard spot at 68°C).

W

Flame presence light

The light is on when the burner is operating.

X

Setting the domestic water
temperature

Adjustment range : 40 °C to 60 °C (Hard spot at 55°C).

Y

"Domestic hot water" on light

The light is on when the heating/domestic hot water reversal valve is in the domestic hot water
position and the circulator pump is operating.

Z

Pressure indicator

Indicates the pressure in the heating circuit from 0.5 to 2.5 bar.

Position Key

Description

Abbreviation Parameter

Range

TC

Collector temperature

[-50.0...+250.0°C]

TS

Tank temperature

[-50.0...+250.0°C]

kWh

Amount of heat

[0...9999 kWh]

PC

Pump regime

[0...100 %]

tc

Self-calibration time

[0...5] minutes

TR

Return temperature

[-50.0...+250.0°C]

TM

Additional temperature
with S3 sensor only (optional)

[-50.0...+250.0°C]