4. Operating instructions

4.3 Changing the settings

4.3.1

Selecting the operating mode

`

Set the 6-position switch T to the desired operating mode.

- -

.

: Shutdown/antifreeze/vent.

- -



: Domestic hot water (Summer).

- -

"

: Heating and domestic hot water (Winter).

4.3.2

Changing the heating temperature

`

Set the temperature of the heating water using button V.

- Minimum = 30 °C
- Maximum = 90 °C
- Hard point = 68 °C

`

The temperature set in shown on the display.



If using an outside temperature sensor, the heating flow
temperature is adjusted automatically.

4.3.3

Changing the domestic hot water temperature

`

Set the domestic hot water temperature using button X.

- Minimum = 40 °C
- Maximum = 60 °C
- Recommended temperature = 55 °C (Hard point) to combine

comfort and economy.

`

The temperature set in shown on the display.

4.4 Stopping the boiler

`

Set the 6-position switch T to

.

(stop / antifreeze / vent).

The boiler goes into standby mode.
The display shows " .. ".



In this operating scenario, the boiler and the domestic hot water
tank are protected against the risk of frost.



Do not shut down power to the control system or drain the
heat-exchanging fluid.

The system is designed in such a way that no special precautions are
necessary during long periods of absence in summer.
The Diemasol A solar control system protects the installation from
overheating.