DE DIETRICH VIVADENS MCR-P 24, MCR-P .._.. MI User Manual
Page 30
![background image](/manuals/329055/30/background.png)
Boiler type
MCR-P 24 MCR-P
24/28 MI
MCR-P
30/35 MI
MCR-P
34/39 MI
Nominal max cold water pressure
(2)
bar
8
8
8
8
Minimum pressure for 11 l/min
(2)
bar
-
1.4
0.4
0.4
Water capacity
litres
-
0.5
0.5
0.5
Combustion products circuit
Connection diameter
mm
80/125
80/125
80/125
80/125
Mass flue gas flow rate (min / max)
Kg/h
10/37
10/47
10/59
10/66
Flue gas temperature 80/60
°C
78
78
74
71.5
Pressure available at the flue gas nozzle
Pa
(1)
50
100
100
140
Condensation water pH 50/30
1 - 7
1 - 7
1 - 7
1 - 7
Electricity characteristics
Power supply voltage (50 Hz)
V
230
230
230
230
Power consumption
W
115
115
150
180
Electrical power circulating pump
W
90
90
125
135
Auxiliary electrical power (nominal output, ex heating
pump)
W
25
25
25
25
Electrical protection index
IPX4D
IPX4D
IPX4D
IPX4D
(1) 1 mbar = 100 Pa, 1 daPa = 1 mmWG
(2) Cold water inlet temperature: 10 °C
7. Technical specifications
MCR-P 24 MCR-P 24/28 MI MCR-P 30/35 MI MCR-P 34/39 MI
29
070513 - 127684-01