WHE 2.24 / WHE 2.24 FF

17/07/2008 - 300011777-001-C

7. Technical characteristics

7 Technical characteristics

Conditions of use:
- Max. safety temperature: 95 °C
- Safety thermostat: 105 °C

WHE 2.24

WHE 2.24 FF

Nominal input power

kW

26.6

25.4

Nominal useful output

kW

24

23.6

Minimum useful output

kW

8.4

8.4

Maximum output

kW

24

23.6

Efficiency (80/60 °C)

%

90.1

92.9

Gas flow rate

Natural gas (Pmax)

m

3

/h

2.77

2.65

Natural gas (Pmin)

m

3

/h

0.97

0.96

Butane / Propane

Kg/h

2.08

1.99

Heating

Minimum output temperature

°C

35

35

Maximum output temperature

°C

80

80

Minimum operating pressure

bar

0.8

0.8

Maximum operating pressure

bar

3

3

Domestic hot water

Minimum output temperature

°C

35

35

Maximum output temperature

°C

60

60

Minimum operating pressure

bar

0.3

0.3

Maximum operating pressure

bar

10

10

Minimum flow

l/min

3

3

Specific flow at

∆t=30K

l/min

11.4

11.4

Combustion products circuit

Mass flue gas flow rate (min / max)

Kg/h

70/75

59/50

Flue gas temperature (min / max)

°C

84/124

98/135

Value CO

2

(min / max)

%

1.8/4.9

2.1/7.1

Maximum pressure at the flue gas nozzle

Pa

-

35

Gas connection

inch

R 3/4

R 3/4

Heating connection

inch

R 3/4

R 3/4

Domestic hot water connection

inch

R 1/2

R 1/2

Electrical connection

V/Hz

230/50

230/50

Electrical power

W

105

150

Expansion vessel capacity

l

8

8

Net weight (without water)

kg

34.7

40.8

Dimensions

mm

750 x 454 x 340

750 x 454 x 340

Insulation class

IP20

IPX4D