4. Operating the appliance

4.3 Stopping the boiler

4.3.1

Switching off

Set the On/Off switch to

{

.



A boiler which is switched off is not protected against frost.



The control panel should always be switched on to take
advantage of the heating pump anti-sticking function

4.3.2

Antifreeze protection

Leave the boiler on standby:
- Turn the boiler thermostat to Min.
- Turn the domestic hot water thermostat to Min.

The pumps start up when the temperature falls below 8°C.
The pumps and the burner start up when the temperature falls below
6°C.

4.3.3

Cleaning the pumps

Leave the boiler on standby:
- Turn the boiler thermostat to Min.
- Turn the domestic hot water thermostat to Min.

The pumps operate for 5 seconds if they have been inactive for more
than 24 hours.

4.3.4

Precautions to take if there is a danger of frost

Heating circuit:
Use a correctly dosed antifreeze to prevent the heating water
freezing. If this cannot be done, drain the system completely. In all
cases, consult the fitter.

Domestic hot water circuit:
Drain the domestic water tank and pipes.

4.3.5

Precautions to take in the event of prolonged shutdown (one year or more)

- Close the gas valve
- The boiler and the chimney must be swept carefully.
- Close the door of the boiler to prevent the internal circulation of air.