3 Description

3.1

Operating principle

The thermodynamic DHW tank uses unheated ambient air or outside

air to prepare DHW.
The refrigerant circuit is a closed circuit in which the R-134a

refrigerant plays the role of an energy carrier.
The heat from the intake air is transferred to the refrigerant in the

finned heat exchanger at a low evaporation temperature.
The refrigerant is sucked in by a compressor in vapour form, which

raises it to a higher pressure and temperature and sends it to the

condenser. In the condenser, the heat extracted in the evaporator and

some of the energy absorbed by the compressor are released into

the water.
The refrigerant is depressurised in the thermostatic expansion valve

and is cooled. The refrigerant can again extract the heat contained in

the inlet air into the evaporator.

3.2

Control panel

3.2.1.

Description of the keys

( - )

Browse keys

MODE

Operating mode selection key

MENU

Key to access the various menus