Code no. Description

Checking / solution

B32

The impressed current anode is in open circuit.

4

Contact the professional who takes care of

maintenance of the appliance.

B33

The impressed current anode is short-circuited.

4

Contact the professional who takes care of

maintenance of the appliance.

B40

Measurement error on the domestic hot water temperature

sensors.

Remarks:

4

This message is only displayed on initial

commissioning.

4

This message disappears after 10 minutes or when
you press the B key.

4

Contact the professional who takes care of

maintenance of the appliance.

If the causes of the problem are still present after several attempts at

automatic start-up, the appliance goes into lockdown mode (also

called failure).
¼see chapter: "Messages (type code EXX)", page 25

6.1.2.

Messages (type code

EXX)

1. The display shows :

- The symbol (!)

- The symbol V

- The fault code (for example E02).

2. After correcting the failure, press the V key for 2 seconds. If

the error code continues to display, search for the cause in the

error table and apply the solution.

Code no. Description

Checking / solution

E00

The parameter storage unit on the PCU electronic board is

defective

4

Contact the professional who takes care of

maintenance of the appliance.

E01

The middle DHW temperature sensor is short circuited

Note: DHW production is not covered

4

Contact the professional who takes care of

maintenance of the appliance.

E02

The middle DHW temperature sensor is open

Note: DHW production is not covered

4

Contact the professional who takes care of

maintenance of the appliance.

E04

The room temperature sensor is short circuited

Note: DHW production is handled by back-up if back-up enabled

4

Contact the professional who takes care of

maintenance of the appliance.

E05

The room temperature sensor is open

Note: DHW production is handled by back-up if back-up enabled

4

Contact the professional who takes care of

maintenance of the appliance.

E06

The evaporator temperature sensor is short circuited

Note: DHW production is handled by back-up if back-up enabled

4

Contact the professional who takes care of

maintenance of the appliance.

E07

The evaporator temperature sensor is open

Note: DHW production is handled by back-up if back-up enabled

4

Contact the professional who takes care of

maintenance of the appliance.

E08

Malfunction on the defrosting function

Note: DHW production is handled by back-up if back-up enabled

4

Contact the professional who takes care of

maintenance of the appliance.

E09

The low pressure pressure switch alarm sounds for more than

120 seconds

Note: DHW production is handled by back-up if back-up enabled

4

Contact the professional who takes care of

maintenance of the appliance.

E10

The low pressure pressure switch alarm has been tripped more

than 3 times during the last 24 hours

Note: DHW production is handled by back-up if back-up enabled

4

Contact the professional who takes care of

maintenance of the appliance.

C003212-B

2"

1

4

3

4

1

2

MENU

MODE

6. Troubleshooting

TWH 200E TWH 300E TWH 300EH

25

03/02/2014 - 7605313-001-02