Disposal of pump, Trouble shooting – BJM Pumps PGV220-575T User Manual

Page 13

Advertising
background image

13

Pump should be inspected at regular intervals.

More frequent inspections are required if the pump is used in a harsh

environment.

Preventative maintenance should be performed to reduce the chance of

premature failure.

Worn impellers and lip seals should be replaced.

Cut or cracked power cords must be replaced.

(Never operate a pump with a

cut, cracked or damaged power cord.)

Seal oil should be checked once per year.

Maintenance should always be done when taking a pump out of service before

storage.

DISPOSAL OF PUMP

When disposing a pump, treat it as a general industrial waste, abiding by federal, state

and local regulations.

TROUBLE SHOOTING

Disconnect the power source to the pump BEFORE attempting

any type of trouble shooting, service or repair.

Warning: Pump will restart automatically when motor over-heat protection switch

cools.

Repair and assembly should be performed by qualified personnel only. Failure to

observe this caution may cause electric shock, injury or fire.

1) Pump fails to run (no running noise)

No electric current in power

distribution line

Power switch in OFF. Or 2 phase or more in open

condition due to fault of the switch

No electric current in pump

cable

Operation switch in OFF. Or 2 phase or more in

open condition due to fault of the switch. Possible

causes: Contact failure of switch, fuse

disconnection, reset-missing of over current relay

Inspect and repair.