Valve construction

• 3/2 way pilot valve with various electrical connection possibilities.

• Valve body with diaphragm, seat seal and A/B manifolds.

• 2 (B) / 4 (A) service ports plus supply and venting ports 1 (P) / 3 (R), as option with internal thread.

Plug-in connectors or pointed hose nipples.

• The valve can be mounted on the modular pneumatic basic rail Type MP05 to form valve banks.

• Can be mounted in any position, preferably with the magnetic system at the top.

• Manual override for hand operation of the valve

3/2 way valve

In de-energised position, pressure inlet 1 closed, outlet port 2 exhausted

3/2 way valve

In de-energised position, pressure inlet 1 connected to outlet port 2

4/2 way valve

In de-energised psotion, pressure inlet 1 connceted to outlet 2, outlet port 4 exhauseted.

Valve operations of the Type 5470 valves

NOTE

NOTE

The valves require no maintenance, even for dry-air operation.

A simple conversion of the 4/2 way valve to a 3/2 way valve is
possible by closing off one of the service ports:
Service port 2

valve operation C;

Service port 4

valve operation D.