Dimensions and weight, Technical data double valve, Temperature-class-specific data – Burkert Type 6144 User Manual
Page 13

13
07 ATEX 2048
English
Technical data Double valve
7.2.1. Protection class
At least IP20 as per IEC 60529, DIN EN60529, (DIN VDE 0470
part1),
7.2.2. Electrical connections
JC09
2 impressed single wires 0.2mm
2
(AWG24)
JC36
2 impressed FEP wires 0.2mm
2
(AWG24)
JF79
Round connector M8
JF80
Rectangular connector 2-pin
JF82
Rectangular connector 2-pin without protective collar
7.3. Dimensions and weight
Length
Width
Height
Ground
18 mm
10 mm
31.5 mm
10 g
8. TECHNICAL DATA DOUBLE VALVE
8.1. Temperature-class-specific data
The maximum permissible output is dependent on the
maximum ambient temperature, the temperature class and
the installation (single or block installation).
The permissible values are listed in the following separate
tables (one for each temperature class).