Burkert Type 8640 User Manual

Page 13

Advertising
background image

13

Installation

Procedure:

Depending on the version, plug the connections in the corre-
sponding working connections or screw them in.

NOTE!

For the plug-in connections the hose pipes must meet the following
requirements:
• Minimum hardness of 40 Shore D (in accordance with DIN

53505 or ISO 868);

• Outer diameter in accordance with DIN 73378 (max. permitted

deviation ± 0.1 mm of the nominal dimension);

• Burr-free, cut off at right angles and undamaged on the outer

diameter;

The hose pipes must be pressed all the way into the plug-in
connections.

7.1.2. Removing the plug-in connections

To detach the pipes, press in the thrust ring and pull out the hose
pipe.

7.1.3. Pneumatic connections -

AirLINE standard

Working connections
for 3/2-way valves

Working connections
for 5/2-way and
2 x 3/2-way valves

Fig. 9:

Pneumatic connections - valve discs

Procedure:

Depending on the version, plug the connections in the corre-
sponding working connections (D6, D1/4) or screw them in (M7).

Connection nipples can be used for threaded versions.

Inscription of the connections:

Label the inscription areas with the data of the valve
connections.