Start-up, Maintenance, Transport, storage, disposal – Burkert Type 8640 User Manual

Page 19

Advertising
background image

19

Start-Up

8. START-UP

WARNING!

Risk of injury from improper operation!
Improper operation may result in injuries as well as damage to the
device and the area around it.
• Before start-up, ensure that the operating personnel are familiar

with and completely understand the contents of the operating

instructions.

• Observe the safety instructions and intended use.
• Only adequately trained personnel may start up the equipment/

the device.

NOTE!

• Switch on the supply pressure.
• Only then switch on the power supply!

Procedures before fluid start-up:

→

Check connections, voltage and operating pressure.

→

Ensure that max. operating data are not exceeded.

→

Check correct assignment of the connections 1 and 3 or 5. They
may by no means be interchanged.

→

Release manual actuation during electrical operation.

9. MAINTENANCE

See “7.2. Fluid deinstallation”, page 15.

10. TRANSPORT, STORAGE, DISPOSAL

NOTE!

Transport damages!
Inadequately protected equipment may be damaged during transport.
• During transportation protect the device against wet and dirt in

shock-resistant packaging.

• Avoid exceeding or dropping below the permitted storage

temperature.

Incorrect storage may damage the device!
• Store the device in a dry and dust-free location!
• Storage temperature: -20 ... +60 °C.

Damage to the environment caused by device components
contaminated with media!
• Ensure the device and packaging are disposed of in an environ-

mentally sound manner.

• Observe applicable regulations relating to refuse disposal and

the environment.

• Observe the national waste disposal regulations.

english