52

AS-Interfaceinstallation

When the supply voltage is applied, the positioner is operating.

→

Make the required basic settings and actuate the automatic adjustment of the positioner, as described in the
chapter entitled “12. Start-up”.

11.6.3. Connection with multi-pole cable and ribbon cable terminal

As an alternative to the bus connection model with 4-pole circular plug, there is the positioner with multi-pole cable
(M12 circular plug) and ribbon cable terminal. The wiring diagram of the circular plug corresponds to the bus con-
nection of the M12 4-pole circular plug (see “Figure 33” and “Figure 34”) and can easily be connected to the ribbon
cable terminal (see “Figure 36”).

Figure 35:

Positioner 8694 with multi-pole cable and ribbon cable terminal

Handling the ribbon cable terminal

The multi-pole cable features a ribbon cable terminal - with M12 plug-in connector branch circuit - for AS-Interface
cable harness. The ribbon cable terminal contacts the AS-Interface cable harness by means of penetration technology
which allows installation by "clipping in" the AS-Interface cable harness without cutting and without removing insulation.

Screws

M12 plug-in con-
nector branch circuit

Work steps:

→

Open the ribbon cable terminal
(loosen screws and remove cover)

→

Insert cable harness conclusively

→

Close ribbon cable terminal again

→

Tighten screws
Slightly undo thread-forming screws
(approx. 3/4 turn to the left) and position them on the
existing tapped bore and screw in.

Figure 36:

Ribbon cable terminal

When the supply voltage is applied, the positioner is operating.

→

Make the required basic settings and actuate the automatic adjustment of the positioner, as described in the
chapter entitled “12. Start-up”.

English

Type 8694