Disassembly

2. Electrical connection

DANGER!

Risk of electric shock!

• Before reaching into the device or the equipment, switch off the power supply and secure to prevent

reactivation!

• Observe applicable accident prevention and safety regulations for electrical equipment!

Circular plug-in connector:

→

Loosen the circular plug-in connector.

Cable gland:

→

Open the positioner: unscrewing the body casing in an anticlockwise direction.

→

Unscrew the screw terminals and pull out cables.

→

Close the positioner.

3. Mechanical connection

→

Loosen the fastening screws.

→

Remove the positioner upwards.

Pneumatic
connections

Positioner

Actuator

Fastening

screws (2x)

Pneumatic

connection to

the actuator

Actuator

Electrical

connection

circular plug-in

connector

Series 21xx

Series 20xx

Figure 42:

Disassembly the positioner