. troubleshooting, Troubleshooting – Burkert Type 8650 User Manual

Page 105

Advertising
background image

105

3.3.

Troubleshooting

Fault

Possible.cause

Remedy

Valves do not switch

No or insufficient operating voltage.

→

Check the electrical connection.

→

Ensure the correct operating voltage.

Manual override not in neutral
position.

→

Move the manual override to the neutral
position.

No or insufficient pressure supply.

→

Design the pressure supply system with
as large a volume as possible (also with
upline devices such as pressure regu-
lators, air conditioners, shut-off valves,
etc.)
Minimum operating pressure 2.5 bar

Incorrect configuration.

→

Use the corresponding module from the
hardware catalogue.

Channel not enabled for use.

→

Change setting of the parameters
(compare section “Acyclic parameters of
the AirLINE Ex modules” in the chapter
“Start-up”)

Too low value set for “Boost time”.

Fuse in the module tripped due to
a short circuit (can only occur in
extreme cases).

→

Replace the electronic module.

Check whether related valves are faulty or
damaged.

Valves switch with a delay
or blow off at the exhaust
ports.

No or insufficient pressure supply.

→

Design the pressure supply system with
as large a volume as possible (also with
upline devices such as pressure regu-
lators, air conditioners, shut-off valves,
etc.)
Minimum operating pressure 2.5 bar

Valves are not in their normal
position (current-free) during the
pressure build-up.

→

Pressurize the valve block before
switching the valves!

Inadequate venting of the exhaust
air ducts due to too small or soiled
silencers (back pressures).

→

Use adequately dimensioned silencers or
expansion vessels.

→

Clean any soiled silencers.

Contamination or foreign matter in
the pilot control or main valve.

→

Replace the valve.

Valve blocks leaking.

Missing or pinched O-rings
between the modules.

Missing or wrongly
positioned profile seals between
valves and basic pneumatic module.

→

Determine the location or the leaks or
missing seals.

→

Install missing seals or replace damaged
seals.

Type 8650

english

Maintenance and Repair

Advertising