Burkert Type 8798 User Manual

Page 17

Advertising
background image

17

Installation

Guide piece

O-ring

Spindle extension

Puck holder

Switch spindle

Spindle (actuator)

Fig. 13: Installing the switch spindle 26xx and 27xx

→

Actuator size 125 and bigger:
remove existing spindle extension and replace with the new one.
To do this, apply some screw locking paint (Loctite 290) in the
tapped bore of the spindle extension.

→

Screw the guide piece into the cover of the actuator using a face
wrench

1)

(torque: 8.0 Nm).

→

To secure the switch spindle, apply some screw locking paint
(Loctite 290) to the thread of the switch spindle.

→

Screw the switch spindle onto the spindle extension. To do this,
there is a slot on the upper side (maximum torque: 1 Nm).

→

Push the puck holder onto the switch spindle until it engages.

1)

journal Ø: 3 mm; journal gap: 23.5 mm

2. install linear remote sensor

→

Push the Remote Sensor onto the actuator. The puck holder
must be aligned in such a way that it is inserted into the guide
rail of the Remote Sensor.

Guide rail

Puck holder

Fig. 14: Aligning the puck holder

→

Press the Remote Sensor all the way down as far as the actuator
and turn it into the required position.

English

Type 8798

Advertising