Start-Up

10.3. electrical connection of the

rotating remote sensor to the
position controller Type 8791 or
Type 8792/8793

→

If necessary, shorten the cable of the Remote Sensor or extend it
to a maximum of 10 m and connect it to the designated M12 cable
gland on the position controller Type 8791 or Type 8792/8793.

→

Connect the 4 wires of the cable, as described in “Tab. 7” and in
the operating instructions of the position controller Type 8791 or
Type 8792/8793, to the appropriate terminals.

→

For potential equalization, connect the shield of the cable to the
grounding connection in the terminal compartment of the position
controller.

Wire
color

configuration

external circuit
8798

8791 or
8792/8793

brown

Supply sensor +

Brown (BN)

S +

white

Supply sensor –

White (WH)

S –

grey

Serial interface
A cable

Grey (GY)

A

pink

Serial interface
B cable

Pink (PK)

B

black

Shielding

Black (BK)

Tab. 7: Wire colors and configuration; rotating Remote Sensor

11.

sTarT-up

11.1. safety instructions

Warning!

risk of injury from improper operation!
Improper operation may result in injuries as well as damage to the
device and the area around it.
• Before start-up, ensure that the operating personnel are familiar

with and completely understand the contents of the operating

instructions.

• Observe the safety instructions and intended use.
• Only adequately trained personnel may operate the equipment/

the device.

No separate steps for starting up are necessary for the Remote
Sensor Type 8798.

→

Carry out the steps outlined for starting up in the operating
instructions of the position controller (Chapter "

Start-up" in the

operating instructions of Type 8791 or Type 8792/8793).