7. START-UP

WARNING!

Risk of injury from improper operation!

Improper operation may result in injuries as well as damage to the

connection element and the surrounding area.
• Before start-up, ensure that the operating personnel are familiar

with and completely understand the contents of the operating

instructions.

• Observe the safety instructions and intended use.

• Only adequately trained personnel may start up the equipment/the

connection element.

• Following assembly, ensure a controlled restart.

• When starting up the equipment, ensure that no unauthorized volt-

age increases and pressure surges can occur.

NOTE!

Damage to the seals when cleaning the pipeline systems.

• Clean the pipeline systems preferably with a cleaning agent which

does not damage the seals.

• Do not clean the connection elements with wire brushes or

machines which cause abrasion of the surface.

• When using mechanical pipeline monitoring devices, ensure

that they do not damage the sealing elements (also the sealing

contour).

Damaged seals must be replaced!

english

9

8. MAINTENANCE

WARNING!

Danger – high pressure and discharge of medium!

• Before loosening the lock nut or locking clamp, always turn off the

pressure and vent the lines.

• Wear protective equipment if media is hazardous.

• Lock nuts or locking clamps of the connection elements on pres-

surized lines may be retightened only by technicians in consider-

ation of special precautions.

• When shutting down the equipment, ensure that no unauthorized

voltage increases and pressure surges can occur.

• Following maintenance, ensure a controlled restart.

Have the connection elements serviced regularly by technicians!

We recommend a maintenance interval of 6 months.
Inspection and maintenance work includes in particular monitoring and

ensuring the
• leak-tightness,

• identification,

• proper mode of operation of the safety and warning devices.

Opening the screw connection Types BBS-03 and BBS-06

Follow safety instructions!

Slacken lock nut or lock screws until they can still hold the pipe

ends.

Vent the pipe ends slightly and slacken them until they no longer

stick to each other.

Remove lock nut or lock screws.

Loosen pipe connection.

Opening the clamp connection Types BBS-05 and BBS-25

Follow safety instructions!

Open wing nut until the locking clamp still holds the pipe

ends.

Vent the pipe ends slightly and slacken them until they no longer

stick to each other.

Remove locking clamp.

Loosen pipe connection.

english

10

9. TRANSPORTATION, STORAGE,

DISPOSAL

NOTE!

Transport damage!
Inadequately protected connection elements may be damaged during

transportation.

• Transport the connection element in a firmly assembled state, pro-

tected against moisture and dirt, in shock-resistant packaging.

• The welding ends must be protected by end caps.

Incorrect storage may damage the connection element.
• Prevent the temperature from exceeding or dropping below the

permitted storage temperature.

• Store the connection element in a dry and dust-free location!

• Store EPDM O-rings and FEP O-rings dry and protected from

UV radiation and for not longer than 3 years.

• Storage temperature -40 to +80°C.

Damage to the environment caused by device components con-

taminated with media.
• Dispose of the device and packaging in an environmentally friendly

manner!

• Observe applicable disposal and environmental regulations.