7. START-UP

WARNING!

Risk of injury from improper operation!

Improper operation may result in injuries as well as damage to the

connection element and the surrounding area.
• Before start-up, ensure that the operating personnel are familiar

with and completely understand the contents of the operating

instructions.

• Observe the safety instructions and intended use.

• Only adequately trained personnel may start up the equipment/the

connection element.

• Following assembly, ensure a controlled restart.

• When starting up the equipment, ensure that no unauthorized volt-

age increases and pressure surges can occur.

NOTE!

Damage to the seals when cleaning the pipeline systems.

• Clean the pipeline systems preferably with a cleaning agent which

does not damage the seals.

• Do not clean the connection elements with wire brushes or

machines which cause abrasion of the surface.

• When using mechanical pipeline monitoring devices, ensure

that they do not damage the sealing elements (also the sealing

contour).

Damaged seals must be replaced!

english

9

8. MAINTENANCE

WARNING!

Danger – high pressure and discharge of medium!

• Before loosening the lock nut or locking clamp, always turn off the

pressure and vent the lines.

• Wear protective equipment if media is hazardous.

• Lock nuts or locking clamps of the connection elements on pres-

surized lines may be retightened only by technicians in consider-

ation of special precautions.

• When shutting down the equipment, ensure that no unauthorized

voltage increases and pressure surges can occur.

• Following maintenance, ensure a controlled restart.

Have the connection elements serviced regularly by technicians!

We recommend a maintenance interval of 6 months.
Inspection and maintenance work includes in particular monitoring and

ensuring the
• leak-tightness,

• identification,

• proper mode of operation of the safety and warning devices.

Opening the screw connection Types BBS-03 and BBS-06

→

Follow safety instructions!

→

Slacken lock nut or lock screws until they can still hold the pipe

ends.

→

Vent the pipe ends slightly and slacken them until they no longer

stick to each other.

→

Remove lock nut or lock screws.

→

Loosen pipe connection.

Opening the clamp connection Types BBS-05 and BBS-25

→

Follow safety instructions!

→

Open wing nut until the locking clamp still holds the pipe

ends.

→

Vent the pipe ends slightly and slacken them until they no longer

stick to each other.

→

Remove locking clamp.

→

Loosen pipe connection.

english

10

9. TRANSPORTATION, STORAGE,

DISPOSAL

NOTE!

Transport damage!
Inadequately protected connection elements may be damaged during

transportation.

• Transport the connection element in a firmly assembled state, pro-

tected against moisture and dirt, in shock-resistant packaging.

• The welding ends must be protected by end caps.

Incorrect storage may damage the connection element.
• Prevent the temperature from exceeding or dropping below the

permitted storage temperature.

• Store the connection element in a dry and dust-free location!

• Store EPDM O-rings and FEP O-rings dry and protected from

UV radiation and for not longer than 3 years.

• Storage temperature -40 to +80°C.

Damage to the environment caused by device components con-

taminated with media.
• Dispose of the device and packaging in an environmentally friendly

manner!

• Observe applicable disposal and environmental regulations.